Difference between revisions of "Auditable events and tamper-resistance (MU3)"

From OpenEMR Project Wiki
Line 13: Line 13:
:(d)(ii)
:(d)(ii)
::*All logging needs to be on by default.
::*All logging needs to be on by default.
:(d)(iii)
::*Logging can only be disabled by a limited set of users.


Final:
Final:

Revision as of 03:17, 14 October 2020

D2.png

Issues:

(d)(2)(i)(A)
  • The audit log must record the information specified in sections 7.1.1 through 7.1.3 and 7.1.6 through 7.1.9 of the standard specified in ASTM E2147-18 and changes to user privileges when health IT is in use.
  • TODO
  • Analyze 7.1.1 through 7.1.3 and 7.1.6 through 7.1.9 of the standard specified in ASTM E2147-18
  • Record changes in user privileges (to fully support this, added logging for when change a user's access control group)
(d)(2)(i)(B)
(d)(2)(i)(C)
  • End-user device encryption is always on per (d)(7), so not applicable.
(d)(ii)
  • All logging needs to be on by default.
(d)(iii)
  • Logging can only be disabled by a limited set of users.

Final:

  • To ensure accurate time, server will need to set up a Network Time Protocol server that supports version 4 Network Time Protocol (NTP) as defined by RFC 5905.

Progress:

  • ASTM E2147-18 7.1.1 through 7.1.3 and 7.1.6 through 7.1.9, 7.2 and 7.4
  • Any changes to a user’s privileges must be captured to meet this criterion (e.g., user account creation, user switches roles and new privileges are assigned, revoking privileges, account disabling, etc.).